A collection of electromagnetic flowmeters from KROHNE

Electromagnetic flowmeters

For all applications with conductive liquids

  • From basic to demanding flow measurements, incl. custody transfer and safety-related applications (up to SIL 2/3)

  • Designs and liner materials for virtually any application – from potable water to extremely adhesive, abrasive and aggressive liquids

  • Large choice of nominal sizes up to DN3000 / 120"

Filter

38 products

Showing 12 of 38

Show more
Electromagnetic flowmeters applications KROHNE

How does an electromagnetic flowmeter work?

Large diameter EMF
WATERFLUX 3050 without straight inlet and outlet runs
WATERFLUX with GPRS module KGA 42 in aboveground part of the pipeline
TIDALFLUX application picture
OPTIPROBE 1100 installed in a DN1200 river water line

How can flow disturbances be minimised for accurate electromagnetic flow measurement?

Magmeter installation recommendation 5DN-2DN

To achieve the specified measurement accuracy, conventional full-bore electromagnetic flowmeters should be installed in accordance with the manufacturer's recommendations. The common industry standard is to provide straight inlet runs of 5 × DN upstream and straight outlet runs of 2 × DN downstream, measured from the centre of the flowmeter. This allows flow disturbances caused by pipe bends, valves or pumps to dissipate, resulting in a stable, fully developed flow profile at the measuring point. These installation recommendations help achieve optimum measurement performance and support compliance with applicable industry standards and guidelines, such as ISO 4064 for water meters.

Flow straightener

Where sufficient straight pipe runs are not available, flow conditioners (flow straighteners) or suitable pipe reducers can help improve the flow profile before the liquid enters the flowmeter. Alternatively, specialised electromagnetic flowmeter designs are available that are less sensitive to disturbed flow profiles and can operate accurately with little or no straight inlet and outlet runs.

Can electromagnetic flowmeters be used without straight inlet and outlet runs?

OPTIFLUX 0D-0D test installation

The benefits of the WATERFLUX design

Compared with conventional electromagnetic flowmeters featuring a full-bore measuring design, the WATERFLUX comes particularly close to the physical ideal of Faraday’s law of induction thanks to its unique measuring tube geometry. For optimum measurement performance, the streamlines should intersect the magnetic field lines as close to perpendicular as possible, i.e. at an angle of 90°. The deliberate reduction and rectangular design of the measuring tube cross-section specifically supports this condition.

The flow is not merely guided by the geometry of the measuring tube; it is deliberately conditioned by physical means. The resulting flow profile is stabilised so that, in the area of the measuring electrodes, the flow lines run largely perpendicular to the magnetic field lines. This favourable flow condition is maintained across a large part of the measuring cross-section, including the areas close to the tube walls. With conventional measuring tubes with a circular cross-section, achieving this optimum geometric alignment between the flow profile and the magnetic field is considerably more difficult due to the different geometry.

Another key advantage of the reduced measuring tube geometry is its energy efficiency. The smaller effective measuring cross-section allows the magnetic coils to be positioned closer together. As a result, the magnetic field required for measurement can be generated with significantly less energy than in a conventional measuring tube with the same nominal diameter and a circular cross-section.

As a result, the WATERFLUX requires significantly less energy to generate the magnetic field and therefore operates with particularly high energy efficiency. This advantage is especially relevant for battery-powered flowmeters: the reduced energy consumption enables significantly longer battery life and, consequently, longer maintenance and service intervals.

Can electromagnetic flowmeters be used in SIL applications?

Icon/Logo Security Integrity Level 2/3 (SIL 2/3)

Yes. Electromagnetic flowmeters can be used in Safety Instrumented Systems (SIS) when they are designed, assessed and certified according to IEC 61508, the international standard for functional safety.

The OPTIFLUX 4400 electromagnetic flowmeter, for example, is certified for use in safety-related applications up to Safety Integrity Level (SIL) 2/3, depending on the system architecture. It supports reliable process monitoring in applications where flow measurement is part of a safety function.

Advanced diagnostic functions help increase plant availability and simplify proof testing. They enable automated partial proof testing of the OPTIFLUX 4400, allowing for extended intervals between full proof tests to increase plant uptime in safety instrumented systems (SIS). The magmeter also features a best-in-class diagnostic test interval and a fault response time of only 2 minutes. If operating outside its specified limits, the flowmeter can issue an alarm to the control room significantly faster than comparable electromagnetic flowmeters on the market.

By combining SIL certification with comprehensive diagnostics, electromagnetic flowmeters can support both functional safety and efficient plant operation in demanding process applications.

Can water flowmeters also be used for sewage?

Wastewater flow measurement

The suitability of an electromagnetic flowmeter (EMF) depends on its design, the materials selected for the liner and electrodes, as well as industry- and country-specific approvals and certifications. However, conditions in sewage applications are often significantly more demanding.

Depending on its composition, sewage can be chemically aggressive and may also have abrasive properties due to the presence of suspended solids and other solid particles. Not every electromagnetic flowmeter designed for water applications is therefore suitable for these conditions in terms of its liner and wetted materials.

As flammable gases such as H₂S can form in sewage applications, the relevant explosion protection requirements must be considered when the flowmeter is used in hazardous areas. Sewage flowmeters are therefore generally designed and configurable so that the electronics and sensor can meet the applicable regional explosion protection requirements.

For a flowmeter specifically designed for potable water applications, such as the WATERFLUX, the sensor's flow cross-section is optimised for drinking water applications. Its design offers significant advantages over conventional electromagnetic flowmeters in this respect. Such a flowmeter can also be used for treated wastewater, for example at the outlet of a wastewater treatment plant. However, it is not suitable for wastewater containing significant amounts of solids or for raw sewage, as the flow-optimised pipe cross-section may limit cleaning by pigging.

In addition, it should be noted that flow in a partially filled, gravity-fed wastewater pipeline cannot be reliably measured even with a conventional EMF designed for wastewater applications. This is the case, for example, in a sewer or when controlling the discharge from a storm overflow basin. Specialised sewage flowmeters such as the TIDALFLUX 2300 are required for this purpose. The TIDALFLUX 2300 was developed for flow measurement in partially filled wastewater pipelines and sewers.

Can electromagnetic flowmeters measure in partially filled pipes?

Can EMFs also be installed underground?

OPTIFLUX 2300 W with special burial coating

Magmeters are ideally suited for buried installation, where they offer a cost-effective alternative to costly and time-consuming flowmeter chambers and manholes in water distribution networks. However, operators need to pay close attention to the appropriate flowmeter specification to protect the installation against corrosion and water ingress.

KROHNE can provide its flowmeters with a special factory-applied coating for buried installation. The coating is designed to protect the meter housing against corrosion for 20 years or more. In addition, flowmeters designed for buried installation feature fully potted electronics housed in a robust stainless steel connection box. Rated IP68 or NEMA 6P, the electronics housing provides additional protection against water ingress and potential damage to the flowmeter.

Diagram of classical and virtual grounding

Which process connections are available for electromagnetic flowmeters?

Electromagnetic flowmeters applications flange connection KROHNE

Electromagnetic flowmeters are available with a wide range of process connections to suit different industries, installation requirements and pressure ratings.

Common options include flanged connections in accordance with standards such as DIN, ASME and JIS, threaded connections, as well as hygienic connections such as clamp connections and ferrules for applications in the food, beverage and pharmaceutical industries. For demanding high-pressure applications, specialised connections such as hub and clamp systems are also available.

For space-constrained installations, flangeless electromagnetic flowmeters in wafer or sandwich design can be installed directly between existing pipe flanges, reducing installation space and weight.

OPTICHECK technology built-in tech icon

OPTICHECK technology built-in

Latest-generation KROHNE electromagnetic flowmeters with integrated OPTICHECK technology (OPTICHECK technology built-in) provide approximately 80 device and application diagnostics, supporting reliable measurement and early detection of process or device-related problems. Diagnostic data can be accessed and configured via the flowmeter's communication and operating interfaces.

Tech icon MPO

Multi-Phase Operation (MPO)

KROHNE's MPO (Multi-Phase Operation) functionality combines advanced diagnostics with optimised signal processing. It enables electromagnetic flowmeters to maintain stable measurement even under severe process conditions, such as gas entrainment, high solids concentrations or electromagnetic disturbances, where conventional magmeters may experience measurement issues.