person infront of chemical plant with a plan in his hands
Tabelle zuordnug geraeten nach kategorie en

In the assessment of explosion hazards, the actual frequency of occurrence of one or the other operating condition is regularly discussed. This is because there is no fixed definition of the terms "constant", "occasional" and "infrequent" used in zoning.  

As a guide, normal operation is the operation of "intended use" according to DIN EN 60079-10. In TRGS 722, "operational disturbances" are included in normal operation:  

Constantly: Temporally predominant (> 50 % of the operating time according to TRGS 722). 

Occasional: May occur at irregular intervals (< 1 % to 10 % of operating time); e.g. venting or sampling. 

Infrequent: Occurs only due to malfunctions (< 1 to 10 h/a); e.g. flanges, connections, fittings, emergency depressurisations. 

EPL: Equipment Protection Level According to IEC 60079-0, equipment is classified into three different protection levels.

The letters "G" and "D" determine whether the equipment is suitable for the gas Ex area (G) or for the dust Ex area. 

Newsletter Subscription: Don't miss any news

With our newsletter, you will receive up-to-date information on trends and developments in the various industries, our products and solutions as well as information on our trade fairs and academies.

Subscribe to Newsletter