SIL 2

Functional safety is a crucial part of plant safety in the process industry. In order to ensure plant safety, most plant operators follow IEC 61508/61511. These rules and standards provide normative guidelines for ensuring the safe operation of process equipment. KROHNE supports its customers with measuring solutions and advice on plant safety. Below is a brief description of the key basic principles for safety loops.

Below is a brief description of the key basic principles for safety loops and what exactly the SIL 2 safety integrity level stands for.

Icon/Logo Security Integrity Level 2 (SIL 2)

Definition of Safety Integrity Levels

Industrial pipelines of oil refinery plant

SIL stands for Safety Integrity Level and indicates the safety level on a device. The standards set out four safety integrity levels for minimising the risks of equipment. For example, a safety function designed in accordance with SIL 1 reduces the plant risk by a factor of 10-100, a function designed in accordance with SIL 2 reduces the plant risk by a factor of 100 – 1000, etc

A safety function (SIS – Safety Integrated Function) as per IEC 61508 essentially consists of three components: 

  • sensor technology that has to identify a critical state in a plant component 
    (e.g. pressure or temperature sensors to identify overpressure or a critical temperature). 

  • a safety system, which uses the sensor technology to identify and assess the critical plant state, and if necessary trigger safety measures to render the plant safe. 

  • actuator technology which allows the plant to achieve a safe state 
    (e.g. gates to shut down plant components, or shut-off valves to stop the flow of material). 

What the SIL logos mean

Icon/Logo Security Integrity Level 2 (SIL 2)

SIL 2 means that the structural constraint allows the relevant device to be used in a single channel (1oo1) in safety equipment up to SIL 2. A type A device (equipment without software, for example variable area flowmeters or relais) can also be used redundantly (1oo2) in SIL 3 safety loops. 

This does not, however, apply to smart field instruments (type B) with software or firmware. These devices can also be used in a redundant configuration in SIL 2 safety equipment at most, as the software in only certified in SIL 2.  

Related products

Compact version of the IFC 400 electromagnetic flow converter

Electromagnetic flow converter for combination with OPTIFLUX and WATERFLUX electromagnetic flow sensors

  • SIL2/3 certified for use in safety instrumented systems (SIS)
  • Multi Phase Operation (MPO): Continuous measurement and stable, repeatable readings – even during major process disturbances such as gas entrainment and solids
  • Compact or remote field housing
  • Advanced OPTICHECK technology built-in diagnostics and NAMUR NE 107 status indication via colour-coded backlit display
  • Various I/O, up to 3 x 4…20 mA HART®7; parameterisation, monitoring and verification via Bluetooth®

Newsletter Subscription: Don't miss any news

With our newsletter, you will receive up-to-date information on trends and developments in the various industries, our products and solutions as well as information on our trade fairs and academies.

Subscribe to Newsletter